Dekorationsartikel gehören nicht zum Leistungsumfang.
Sprache:
Englisch
33,20 €
Versandkostenfrei per Post / DHL
Lieferzeit 4-7 Werktage
Kategorien:
Beschreibung
This book offers introduction of Power system protection relay characteristics, operational behavior of distance relay and proposed simulation based technique for fault detection. In recent years, we have seen several catastrophic failures of power systems throughout the world. The usual scenario of such events is that the power system is in a stressed state, followed by faults on critical facilities, followed by unanticipated tripping of other facilities, finally leading to system breakup and blackouts. Distance relay plays an important role in the protection of transmission lines. In conventional transmission line protection, a three - zone stepped directional distance system is used to provide the primary as well as remote backup protection. However, accuracy of this measurement may be affected by the power disturbances such as power swings and switching actions, over loading resulting load encroachment. The quality of this measurement may cause mal-operation of distance relays which in turn may affect the reliability of the whole protective scheme. This book describe how Simulink/MATLAB simulator under L-G faults conditions detects the distance relay third zone malfunctioning.
This book offers introduction of Power system protection relay characteristics, operational behavior of distance relay and proposed simulation based technique for fault detection. In recent years, we have seen several catastrophic failures of power systems throughout the world. The usual scenario of such events is that the power system is in a stressed state, followed by faults on critical facilities, followed by unanticipated tripping of other facilities, finally leading to system breakup and blackouts. Distance relay plays an important role in the protection of transmission lines. In conventional transmission line protection, a three - zone stepped directional distance system is used to provide the primary as well as remote backup protection. However, accuracy of this measurement may be affected by the power disturbances such as power swings and switching actions, over loading resulting load encroachment. The quality of this measurement may cause mal-operation of distance relays which in turn may affect the reliability of the whole protective scheme. This book describe how Simulink/MATLAB simulator under L-G faults conditions detects the distance relay third zone malfunctioning.
Über den Autor
Manan Desai est chef du département de génie électrique à l'Université Dr. Subhash, Junagadh.Jaydip Ranva est chercheur au département d'électricité de l'Université Dr. Subhash, [...] domaines de recherche sont : le véhicule électrique et le système électrique.
Details
| Erscheinungsjahr: | 2018 |
|---|---|
| Fachbereich: | Elektrizität/Magnetismus/Optik |
| Genre: | Importe, Physik |
| Rubrik: | Naturwissenschaften & Technik |
| Medium: | Taschenbuch |
| Inhalt: | 64 S. |
| ISBN-13: | 9786139827084 |
| ISBN-10: | 6139827086 |
| Sprache: | Englisch |
| Einband: | Kartoniert / Broschiert |
| Autor: | Desai, Manan |
| Hersteller: | LAP LAMBERT Academic Publishing |
| Verantwortliche Person für die EU: | LAP Lambert Academic Publishing, Brivibas Gatve 197, ?-1039 Riga, customerservice@vdm-vsg.de |
| Maße: | 220 x 150 x 4 mm |
| Von/Mit: | Manan Desai |
| Erscheinungsdatum: | 05.06.2018 |
| Gewicht: | 0,113 kg |